PMD 1208LS DRIVER

The accuracy specs are warranted at 25 deg C for 1 year from original ship date. In general, the boards had performed well for our acquisition, analyzing and storing data. Also, what is the difference between hardware paced and software paced output? Please consider both single-ended and differential mode pinout. The trigger has a latency of 10 uSec with a minimum pulse width of 1 uS. To read current you need to pass “Current” through something, like a resistor.

Uploader: Nasho
Date Added: 21 September 2007
File Size: 57.98 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 41937
Price: Free* [*Free Regsitration Required]

The trigger can be configured for rising or falling edge, high or low level TTL signals. A race car typically has several volt referenced sensors. You can view the Manual at the following link: Great Overall Product This unit works great for our pressure 1208lx recording. Perhaps the cause is a loose wire.

Ask a New Question. Best Regards, Shane Job Title: You can download the manual from our web site here: We have used this model device in the past and were pleased with it’s ease of use with data we needed.

Using PMD ls with simulink? – MATLAB Answers – MATLAB Central

I was wondering if this converter does that or not. Do you recommend this product? Bioprocessing 55 months ago.

Related Drivers  DRIVER: SATELLITE A500-19W

Basically the —Plus is an updated model with some enhancements. We will send you an email once your question has been posted. Keep this wire pmf short as possible to minimize noise false clocking. I tried it with two different PCs, one is running Windows 7 Sp1 64bit, the other is running windows 8.

USB Bit and Bit Multifunction DAQ Devices and Boards – Measurement Computing

How much often the device needs to be calibrated? Ideal as a bridging product in a wide range of instrumentation and control applications, the PMDLS will be of particular interest to original equipment manufacturers who wish to buy in the hardware but stay in control of the software. This setting must be done on a global basis. I have not tested it for a higher accuracy so I don’t know from there.

You’ve got a few things to watch out for, but nothing too big, assuming you’re trying to measure low current. Works great in 2108ls application and it’s nice to have a commercially available product for no lead times in production. What is the total accuracy of this device when measuring differential voltage? I’ve tried using the counter input and TracerDAQ to measure frequency.

Related Drivers  ASUS K40IJ CAMERA DRIVER

A good example is installed with ULx, named: Associate Professor of Physics Industry: Just what I ordered Happy with my purchase Job Title: Hello CTR – We can absolutely get you up and running with this project. Reload the page to see its updated state. Yes, I recommend this product!

Select a Web Site

Also, what is the difference between hardware paced and software paced output? Tags data acquisition toolbox pmd ls. The trigger has a latency of 10 uSec with a minimum pulse width of 1 uS.

The product was reasonably priced and in both cases we received the unit sooner that was estimated at the time order was placed. To drive large loads, you will need additional external circuitry.